  • 01Hard energy saving

    High efficiency and energy saving: The luminous efficacy can reach up to 175lm/W, suitable for ambient temperatures ranging from -20℃ to 45℃

    Intelligent dimming: Equipped with an intelligent dimming controller, it can achieve high-precision output power ranging from 0 to 100% according to different illuminance requirements

    Control mode: It can be optionally equipped with human body sensor, illuminance sensor and multi-functional key panel to achieve multiple control methods, which is energy-saving, efficient and intelligent

    Super strong heat dissipation: Professional heat dissipation structure design and high-quality sheet metal shell effectively reduce the temperature of the light source and power supply. The service life can be continuously operated for 50,000 hours at 45° C ambient temperature

02Soft energy conservation

Human body sensing mode

When a person is sensed, the brightness of the lamp is 100%. After the person leaves for 30 seconds, enter the dim mode. The brightness of the lamp is 10% and it remains in the dim mode for 1 minute. During this period, if no one passes by, the lights will turn off automatically.

Human body sensing mode

When a person is sensed, the brightness of the lamp is 100%. After the person leaves for 30 seconds, enter the dim mode. The brightness of the lamp is 10% and it remains in the dim mode for 1 minute. During this period, if no one passes by, the lights will turn off automatically.

More

Timing control mode

The lighting fixtures are set to a timed control mode. At 6:30, the fixtures automatically enter the forced lighting mode and cancel the human body sensor function. At 17:00, the fixtures automatically turn on and restore the default brightness to 30%, enabling the human body sensor control mode.

Timing control mode

The lighting fixtures are set to a timed control mode. At 6:30, the fixtures automatically enter the forced lighting mode and cancel the human body sensor function. At 17:00, the fixtures automatically turn on and restore the default brightness to 30%, enabling the human body sensor control mode.

More

Illuminance sensing mode

The illuminance collected by the sensor is greater than 100lux, and the ambient illuminance meets the requirements of daily use. The floodlight will automatically turn off. When the illuminance collected by the sensor is less than 50lux and the ambient illuminance cannot meet the daily usage requirements, the floodlight will automatically turn on, restore the brightness by 10%, and simultaneously activate the human sensor control mode.

Illuminance sensing mode

The illuminance collected by the sensor is greater than 100lux, and the ambient illuminance meets the requirements of daily use. The floodlight will automatically turn off. When the illuminance collected by the sensor is less than 50lux and the ambient illuminance cannot meet the daily usage requirements, the floodlight will automatically turn on, restore the brightness by 10%, and simultaneously activate the human sensor control mode.

More

Centralized control mode

Divide the building area into zones and formulate lighting scenarios based on the functions and usage habits of each area. Pre-set standard scene templates for various industries, such as "circadian rhythm lighting" for offices and "Inspection safety light tracks" for factories, etc.

Centralized control mode

Divide the building area into zones and formulate lighting scenarios based on the functions and usage habits of each area. Pre-set standard scene templates for various industries, such as "circadian rhythm lighting" for offices and "Inspection safety light tracks" for factories, etc.

More